
25
11 COMPARATOR OUTPUT (AD-8922A-04)
The weighing data is compared with the upper and lower limit values and the results of the comparison are
contact-output in three levels of HI OK LO . The upper and lower limit values are set in the function setting.
Whether or not to sound the buzzer according to the results can be selected.
Note: When the AD-8922A-04 is installed, the pin assignment (DIN 8-pin), of the RS-232C serial
interface, to connect an external device, will be changed.
11-1 Comparator Output Specifications
Accessories
DIN connector (Plug) 1 pc.
Instruction manual 1 copy
Panel view
Comparator output (COMP.OUT)
Maximum contact voltage: 100 VDC
Maximum contact current: 100 mA DC
Maximum contact resistance: 20 Ω
Comparator output judgement conditions (when upper limit value
≥lower limit value):
Weighing data
>upper limit value: Activates the HI comparator output.
Upper limit value
≥weighing data≥lower limit value: Activates the OK comparator output.
Weighing data
<lower limit value: Activates the LO comparator output.
Reference value setting: Input the upper and lower limit values digitally.
Contact output: Select whether or not to compare, using “Cp” of the function setting.
Buzzer: Select whether or not to sound the buzzer, using “bep” of the function
setting.
AD8922A
OP-04
BALANCE
/SCALE
COMP.OUT
Comentários a estes Manuais