A&D Multi Function Weighing Indicator AD-4402 Especificações Página 48

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 146
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 47
Page 46 AD-4402
7.3.4.
7.3.4.7.3.4.
7.3.4. Initial Flow S
Initial Flow SInitial Flow S
Initial Flow Sequence
equenceequence
equence
The initial flow sequence is used to prevent the material from scattering before the
batch weighing when a liquid or powder is weighed. When the sequence starts, the
dribble gate is opened first, the medium gate is opened next and the full gate is
opened last. The parameter can be set in each material code.
Concerning Parameters of the Function
Using this sequence to prevent the material from scattering.
Set the following parameters in each material code.
Initial DF (Initial dribble flow)
Initial MF (Initial medium flow)
Editing these parameters.
Edit the parameters in the function mode.
[Function] - [Function setting] - [MatEDIT] - [Edit]
Inhibiting comparison during the sequence.
[5q f-35] Store the time of the dribble flow comparison inhibit timer.
[Function] - [Function setting] - [Sequence] - [Timer] - [Dribble flow
comparison interrupt timer]
[5q f-34] Store the time of the medium flow comparison inhibit timer.
[Function] - [Function setting] - [Sequence] - [Timer] - [Medium flow
comparison interrupt timer]
Vista de página 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 145 146

Comentários a estes Manuais

Sem comentários