Page 116 AD-4402
Category address
:
[Function] - [Function setting] - [Sequence] - [Control]
Category
address
symbol
Name Descriptions
Range
and
choices
Default
5q f-11
Batch start settings
Select an action at starting the weighing
sequence.
Bit 1: When loading it above zero
band, start the sequence.
Bit 2: Not used
Bit 3: Automatic tare at the starting
sequence
0: No (Does not work)
1: Yes (Works)
000 to
111
000
5q f-12
Nozzle control
Bit 1: Use nozzle control.
"Nozzle down" operation signal
is output at starting the
sequence.
Bit 2: Nozzle contact stop sequence
Use start delay timer to prevent
weighing error at touching the
hopper.
Bit 3: "Nozzle up" after compensate.
0: No (Not used)
1: Yes (Use)
000 to
111
000
5q f-13
Eval conditions
After dribble flow, select the stablility
condition of comparison. Refer to
E
val
delay timer [5qf-37].
0: Timer is up
Compare when time is up.
1: Stable and timer is up
Compare when weighing is stable
and the time is up.
2: Stable or timer is up
Compare when weighing is stable or
the time is up.
0 to 2 1