Vista de página 43
Page 42 AD-4402
Drawing: Loss-in Weight of Sequential Weighing
0
Weighing value
Start command, Input
Dribble flow, Output
Batch finish, Output
Over weight, Output
Under weight, Output
Medium flow, Output
Full flow, Output
Material code, Input
Start delay time
r
Batch monitoring time
r
Dribble flow comparison interrupt time
r
Medium flow comparison interrupt time
r
Full flow comparison interrupt time
r
Eval delay time
r
Stable, Output
Acceptable, Output
5qf
-
3
1
5qf-37
5qf
-
33
5qf-35
5qf-34
Tare command, Input
Final value
Enable to use automatic tare
Comparison
Select a mode
at 5qf-05
Gross weight
Full filling
Zero band
Net weight
Optional preliminary
Preliminary
Free fall
5qf-32
The active code is only read at
each start. And kee
p
it.
Monitor to su
pp
l
y
it
Time until suppl
y
in
g
it
5qf-43
batch finish output
on
- Final value
or -Target weight
- Final value + Free fall
- Final value + Preliminary
- Final value + Optional preliminary
Full filling value
Vista de página 43