A&D GF-10K Especificações

Consulte online ou descarregue Especificações para Balanças de cozinha A&D GF-10K. A&D GF-10K Product specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
MC-10K
MC-30K
1WMPD4002203A
Vista de página 0
1 2 3 4 5 6 ... 67 68

Resumo do Conteúdo

Página 1

MC-10K MC-30K 1WMPD4002203A

Página 2 - This Manual and Marks

8 3. Precautions To get the optimum performance from the balance and acquire accurate weighing data, note the following: 3-1. Before Use The m

Página 3 - Contents

9 3-2. During Use Discharge static electricity from the weighing material. When weighing sample (plastics, insulator, etc.) could have a static

Página 4

10 Do not allow the balance to be immersed in water. Even though the balance complies with IP code, the balance will not withstand being completel

Página 5 - 1. Introduction

11 4. Display Symbols And Key Operation Key Operations Key operation affects how the balance functions. The basic key operations are: "

Página 6 - 1-3. Compliance

12 5. Weighing Units With the balance, only the unit “g” (gram) was set at the factory. The following weighing units and weighing modes are ava

Página 7 - AC Adapter

13 The tables below indicate the weighing capacity and the minimum display for each unit, depending on the balance model. When a measurement

Página 8

14 6. Weighing 6-1. Selecting a Weighing Unit (Mode) Press the MODE key to select a unit or mode for weighing. The unit “g” (gram) was set at the

Página 9 - 2-2. Installing the Balance

15 Weight class and recommended measuring range 6-2-3. When Building into a System z When a special weighing pan is to be designed, th

Página 10 - 3. Precautions

16 7. Weighing Speed Adjustment / Self Check Function 7-1. Weighing Speed Adjustment This function detects the influence on weighing that is caus

Página 11 - 3-3. After Use

17 7-2. Self Check Function with Response Adjustment This function automatically updates the response adjustment by analyzing the influence

Página 12 - 3-4. Power Supply

This Manual and Marks All safety messages are identified by the following, “WARNING” or “CAUTION”, of ANSI Z535.4 (American National Standard Ins

Página 13 - Display

18 8. Calibration 8-1. Calibration Group The balance has the following modes as a calibration group. Calibration Automatic self calibration (Cali

Página 14 - 5. Weighing Units

19 Caution on using an external weight The accuracy of an external weight can influence the accuracy of weighing. Select an appropriate weight

Página 15

20 8-3. One-Touch Calibration Calibration using the internal mass This function calibrates the balance using the internal mass. The only operati

Página 16 - 6. Weighing

21 8-4. Calibration Using an External Weight This function calibrates the balance using an external weight. When the MC-10K is used Step 1

Página 17 - (Displayed value)

22 8-5. Calibration Test Using an External Weight This function tests the weighing accuracy using an external weight and outputs the result. Thi

Página 18 - 0. 000

23 8-6. Correcting the Internal Mass Value The balance can correct the internal mass value within the range shown below. This function correct

Página 19 - CH . . .

24 CAL key...To cancel the correction and display the next menu item of the function table. Step 10 Press the CAL key to return the w

Página 20 - 8. Calibration

25 9. Function Switch And Initialization 9-1. Permit or Inhibit The balance stores parameters that must not be changed unintentionally (Examp

Página 21 - Caution

26 9-2. Initializing the Balance This function returns the following parameters to factory settings. Calibration data Function table The sam

Página 22 - 8-3. One-Touch Calibration

27 10. Function Table This function table reads or rewrites the parameters that are stored in the balance. These parameters are maintained in

Página 23 - When the MC-10K is used

Instruction manual 1 GX-K series, GF-K series Contents Basic Operation 1. Introduction ...

Página 24

28 10-3. Details of the Function Table Class Item and Parameter Description 0 Fast response, sensitive value FAST 1 MID.Cond Condition 2 Slow

Página 25

29 Class Item and Parameter Description 0 OFF Cp-b Main display comparison 1 ON Displays the results on the main portion of the display in pl

Página 26 - 0. 00

30 Class Item and Parameter Description 0 No output d-no Data number output 1 Output Refer to the GX-K manual "12. Data Memory" 0 No

Página 27 - 9-1. Permit or Inhibit

31 Class Item and Parameter Description Unit Unit Refer to "5. Weighing Units". C5 in Internal mass correction Displayed only when

Página 28

32 10-4. Description of the Class "Environment, Display" Condition ( Cond ) Cond 0 This parameter is for sensitive response to the fluc

Página 29 - 10. Function Table

33 10-5. Description of the Item "Data Output Mode" The parameter setting of "Data output mode (prt)" applies to the perfo

Página 30

34 Interval memory mode The weighing data is periodically stored in memory. Example For periodical weighing without a personal computer comma

Página 31

35 KF format 5if type 2 This is the Karl-Fischer moisture meter format and is used when the peripheral equipment can only communicate using th

Página 32

36 10-6-1. Description of the Data Format Added to the Weighing Data ID number dout 5-id 1 The number to identify a specific balance. This for

Página 33

37 CRLFCRLFCRLFCRLFCRLFA&DDPKFMTNU 12. 700 g 0000. 000 gCRLFCRLFCRLFLFCRLFCRLFCRLFCRA&DDPKFMTNU -1836. 900 gCRLFA&DNU -0

Página 34 - Span calibration ( 5pn )

2 10-5. Description of the Item "Data Output Mode" ... 33 10-6. Description o

Página 35 - Stream mode

38 11. ID Number And GLP Report The ID number is used to identify the balance when Good Laboratory Practice (GLP) is used. The ID number is

Página 36 - Stable header (Counting mode)

39 11-2. GLP Report Set the following parameters to output the report. To print the report, set the "GLP output (info)" parameter

Página 37 - Unstable value

40 Calibration report using an external weight Setting of "info 1" Setting of "info 2" AD-8121 printer format General

Página 38 - Data number

41 Title block and end block When weight values are recorded as GLP data, a "Title block" is inserted at the beginning and an "E

Página 39 - 10-7. Data Format Examples

42 12. Standard Input And Output Interface 12-1. RS-232C and External Contact Input D-Sub 25 pin numbers D-Sub 25 pin assignments Pin

Página 40

43 RS-232C Terminals External contact input By connecting pin 18 (PRINT command) to pin 7, or pin 19 (RE-ZERO command) to pin 7

Página 41 - 11-2. GLP Report

44 1 2 3 4MODEON1 2 3 4MODEON 12-2. Connection to Peripheral Equipment 12-2-1. Connection to the AD-8121B Printer Preset the following p

Página 42

45 12-2-2. Connection to a Computer and the Use of WinCT The balance is of the DCE type (Data Communication Equipment), which can be connecte

Página 43

46 13. Commands 13-1. Command List Note A command has a terminator added, that is specified using "5if Crlf" of the function table, a

Página 44 - RS-232C

47 Commands to control the balance R Same as the RE-ZERO key SMP Same as the SAMPLE key. U Same as the MODE key UN:mm Recalls the unit mass value

Página 45 - External contact input

3 1. Introduction This manual describes how the MC Series Mass Comparator Balances, MC-10K and MC-30K, work and how to get the most out of the

Página 46 - 1 2 3 4

48 R command When a communication error has occurred due to external noise, or a parity error has occurred due to transmission

Página 47

49 14. Extended Function The MC series balance has several extended functions equipped for special applications or to troubleshoot when using

Página 48 - 13. Commands

50 14-1. Description of "Averaging range" and "Averaging time" 14-1-1. Averaging Range ( f1-b ) and Averaging Time ( f1-t ) 1.

Página 49 - MODE key

51 14-1-2. Filter Depending on Differences in the Amount to Deliver Powdery and Liquid Material z When the weight value is not stable even wi

Página 50

52 15. Maintenance 15-1. Treatment of the Balance In normal use, the balance can be cleaned with water. But, keep the following precautions so th

Página 51 - 14. Extended Function

53 16. Troubleshooting 16-1. Checking the Balance Performance and Environment The balance is a precision instrument. When the operating e

Página 52

54 16-2. Error Codes Display Error code Description EC,E11 Stability error The balance can not stabilize due to an environmental problem. Check

Página 53

55 Display Error code Description Automatic response adjustment zero error The automatic response adjustment can not be performed because the

Página 54 - 15. Maintenance

56 Display Error code Description EC,E03 Timeout error If the timeout parameter is set to "t-Up1", the balance did not receive the next

Página 55 - 16. Troubleshooting

57 17. Specifications MC-10K MC-30K Weighing capacity 10.1 kg 31 kg Maximum display 10.100844 kg 31.00844 kg Minimum weighing value (1 di

Página 56 - 16-2. Error Codes

4 1-3. Compliance 1-3-1. Compliance with FCC Rules Please note that this equipment generates, uses and can radiate radio frequency energy. This e

Página 57

58 17-1. External Dimensions Unit: mm

Página 58 - 16-4. Asking for Repair

59 17-2. Options and Peripheral Instruments AX-MC10K/30KPAN Auto-centering Pan This option consists of an auto-centering pan, a breeze brea

Página 59 - 17. Specifications

60 Order code Name and description AD-1682 Rechargeable Battery This option allows use of the balance in a place where AC power is not available

Página 60 - 17-1. External Dimensions

61 18. Terms/Index 18-1. Terms Calibration Adjustment of the balance so that it can weigh accurately. Calibration weight A weight used for

Página 61 - AD-8121B Printer

62 Stable value The stable weight data, indicated by the illuminated stabilization indicator. Stabilization time Time required after a sample be

Página 62

63 18-2. Index Keys and symbols CAL key ... 11 MODE key ...11, 14 ON OFF

Página 63 - 18. Terms/Index

64 erCd AK, Error code ... 30 error 1 Stability error ... 54 error 2 Out of the

Página 65 - 18-2. Index

3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 JAPAN Telephone: [81] (3) 5391-6132 Fax: [81] (3) 53

Página 66

5 2. Unpacking And Installing The Balance The balance is a precision instrument. Unpack the balance carefully. Keep the packing material to be

Página 67

6 2-1. Auto-centering Pan (AX-MC10K/30KPAN) Installation Procedure Caution: During installation, do not to apply excessive force to the balance. Wh

Página 68

7 2-2. Installing the Balance Install the balance as follows: 1 Refer to "3. Precautions" for installing the balance. 2 Install th

Comentários a estes Manuais

Sem comentários